⑴ 璋佹湁鑱旀兂THINKPAD鐨凚ioS瀵圭収琛ㄥ晩緇欐垜鍙戜竴涓嬭阿璋㈠晩錛[email protected]
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 1 欏 鍏 9 欏
ThinkPad BIOS璁劇疆鎵嬪唽
鏈鏂囦互ThinkPad T61/T61P 鐨凚IOS涓轟緥錛岃︾粏浠嬬粛ThinkPad 鏈哄瀷BIOS鐨勮劇疆錛屽叾瀹冩満鍨嬪彲鍙傝冿紝
璁劇疆閫夐」鍩烘湰涓鑷淬
BIOS錛孊asic Input and Output System錛屾帶鍒朵簡鏁翠釜璁$畻鏈烘墍鏈夌‖浠剁殑璁劇疆銆傚綋鎴戜滑寮鍚疶60 鏃訛紝灞忓箷
涓嬫柟浼氬嚭鐜扳淧ress F1 for ThinkPad BIOS Setup Utility鈥濇椂錛屾寜涓 F1閿錛岃緭鍏ユg『鐨勫瘑鐮佹垨鍒蜂笅鎸囩汗錛堝
鏋滆劇疆浜咮IOS瀵嗙爜鐨勮瘽錛夛紝灝嗕細榪涘叆BIOS璁劇疆鐣岄潰銆
鍦═hinkPad BIOS 璁劇疆鐣岄潰涓錛屽垎涓轟笂涓嬩袱閮ㄥ垎錛屼笂鍗婇儴鍒嗗寘鍚獵onfig 銆丏ate/time 銆丼ecurity銆丼tartup 銆
Restart 銆丠DD Diagnostics Program 絳夊叚涓璁劇疆閫夐」錛屼笅鍗婇儴鍒嗕富瑕佹樉紺烘湰鏈虹殑涓浜涚郴緇熶俊鎮銆
涓銆佹湰鏈虹郴緇熶俊鎮
鏄劇ず鍐呭 瀹炰緥 璇存槑
BIOS Version 1.14 錛7LET44W錛 鏈哄櫒褰撳墠鐨凚IOS鐗堟湰
BIOS Date錛圷ear-Month-Day 錛 2007-06-27 褰撳墠BIOS鐗堟湰鐨勫彂甯冩棩鏈
Embedded Controller Version 1.06
鍐呭祵鎺у埗鍣ㄧ殑鐗堟湰錛堝繀欏諱笌瀵瑰簲鐨凚IOS
閰嶅悎浣跨敤錛
System-Unit Serial Number 766014AL3A3068
7660涓烘満鍨嬶紝14A 涓篗odel錛孡3A3068 涓
鏈鴻韓搴忓垪鍙鳳紙SN錛
CPU Type Genuine Intel錛圧 錛 CPU T7300 CPU 鐨勫瀷鍙鳳紝濡傝嫳鐗瑰皵CPU T7300
CPU Speed 2.00GHz CPU 鏈楂樻椂閽熼戠巼錛屽2.00GHz
Installed Memory 1024MB 宸插畨瑁呯殑鍐呭瓨澶у皬錛屽1024MB
UUID
Mac Address錛圛nternal Lan 錛 00 1A 6B CE C9 3E 鍐呯疆緗戝崱鐨凪ac 鍦板潃錛堢綉鍗$殑鐗╃悊鍦板潃錛
浜屻丆onfig錛堥厤緗錛
浣跨敤閿鐩樹笂涓嬫寜閿縐誨姩楂樹寒搴︽潯鍒癈onfig 錛屾寜鍥炶濺閿榪涘叆 Config 璁劇疆欏癸紝鍒嗗埆鏈変互涓嬪瓙閫夐」錛
錛堜竴錛塏etwork錛堢綉緇滐級
1 銆乄ake On Lan
Enabled錛氬彲浠ラ氳繃灞鍩熺綉涓鐨勫叾瀹冭$畻鏈哄皢絎旇版湰鐢墊簮鎵撳紑錛屽苟涓斿惎鍔ㄧ瑪璁版湰錛汥isabled 鍒欑佺敤榪欓」
鍔熻兘銆傚綋璁劇疆浜嗙‖鐩樺瘑鐮侊紝璇ュ姛鑳芥棤鏁堛傦紙鏍規嵁闇瑕侀夋嫨錛屼竴鑸涓浜虹敤鎴烽夋嫨Disabled銆傦級
2 銆丗lash Over Lan
Enabled錛氬厑璁稿彲浠ヤ粠涓涓鍙鐢ㄧ殑灞鍩熺綉涓錛岄氳繃緗戠嚎錛屾潵鍗囩駭鏈鏈虹殑BIOS錛汥isabled錛氱佺敤榪欓」鍔熻兘銆
錛堟牴鎹闇瑕侀夋嫨錛屼竴鑸涓浜虹敤鎴烽夋嫨Disabled銆傦級
3 銆丒thernet Network Option Rom
Enabled錛氬惎鐢錛屽彲浠ラ氳繃鍐呯疆緗戝崱瀹炵幇緗戠粶鍚鍔錛屽悓鏃舵樉紺烘湰鏈虹殑 Mac 鍦板潃錛汥isabled錛氱佺敤銆傦紙寤
璁閫夋嫨Disabled錛屼箣鍓嶆湁ThinkPad T60鐢ㄦ埛鍙嶆槧寮鏈虹綉鍗℃姤閿欙紝鍘熷洜鍦ㄤ簬鎰忓栨帀鐢碉紝瀵艱嚧緗戝崱Rom鎹熷潖錛
鍙﹀栵紝緗戠粶鍚鍔ㄤ釜浜虹敤鎴蜂嬌鐢ㄧ殑涓嶅氥傦級
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 2 欏 鍏 9 欏
4 銆丠ard Drive Direct Memory Access錛圖MA錛夛紙紓佺洏楂橀熺紦瀛橈級
Enabled錛氬惎鐢錛汥isabled錛氱佺敤銆傦紙寤鴻閫夋嫨 Enabled 鍚鐢ㄥ憡璇夌紦瀛橈紝鍙浠ユ湁鏁堢殑鎻愬崌紓佺洏鎬ц兘錛岄檷
浣嶤PU鍗犵敤鐜囥傦級
5 銆両nternal Wireless Device 錛堝唴緗鏃犵嚎璁懼囷級
On錛氬惎鐢ㄦ棤綰胯懼囷紱Off錛氬叧闂鏃犵嚎騫挎挱銆傦紙鏈欏瑰叾瀹炲氨鏄鍏充簬鍐呯疆鏃犵嚎緗戝崱鐨勯夋嫨錛屼嬌鐢ㄦ棤綰誇笂緗戱紝
閫夋嫨On錛涘傛灉涓嶄嬌鐢ㄦ棤綰誇笂緗戱紝鍙浠ラ夋嫨Off銆傦級
錛堜簩錛塖erial Port 錛堜覆鍙o級
濡傛灉瑕佸惎鍔ㄤ覆鍙o紝璇烽夋嫨Enabled錛孊ase I/O address鍜孖nterrupt 浣跨敤榛樿よ劇疆灝卞彲浠ワ紝濡傛灉涓庡叾瀹冪‖
浠舵湁鍐茬獊錛屽彲浠ヨ嚜琛屾洿鏀癸紱Disabled 鍒欑佺敤榪欓」鍔熻兘銆傦紙ThinkPad 鏂版満鍨嬪熀鏈涓婂苟涓嶅唴緗榪欎釜鎺ュ彛浜嗭紝鍙
浠ラ夋嫨Disabled銆傦級
錛堜笁錛塒arallet Port錛堝苟鍙o級
鍚鍔ㄥ苟鍙o紙鎵撳嵃鍙o級錛岄夋嫨Enabled錛孊ase I/O address 鍜孖nterrupt 浣跨敤榛樿よ劇疆灝卞彲浠ワ紱鍚﹀垯閫夋嫨Disabled
紱佺敤榪欓」鍔熻兘銆侻ode鏈4 縐嶅彲閫夋ā寮忊斺擝i-directional銆丱utput only銆丒PP 銆丒CP 錛屾牴鎹闇瑕佽繘琛岄夋嫨銆
錛圱hinkPad 鏂版満鍨嬪熀鏈涓婂苟涓嶅唴緗榪欎釜鎺ュ彛浜嗭紝寤鴻閫夋嫨 Disabled錛屼絾鏄鍦ㄧ郴緇熸棩蹇楀唴浼氭湁閿欒鏃ュ織錛
騫朵笉褰卞搷銆傦級
錛堝洓錛塒CI
璁劇疆PCI 鐨勪腑鏂鍦板潃錛屼繚鎸侀粯璁ゅ嵆鍙錛屽傛湁鍐茬獊錛屽彲鑷琛屾洿鏀廣
錛堜簲錛塙SB
1 銆乁SB BIOS Support
2 銆丄lways On USB
Enabled錛氬惎鐢ㄥ USB 鎺ュ彛鐨勮蔣椹卞拰鍏夐┍鐨勫惎鍔錛堝湪榪愯 DOS紼嬪簭鐨勬椂鍊欙紝鍙浠ヨ妭綰 16KB 鐨勫唴瀛橈級錛
閫夋嫨Disabled 紱佺敤姝ら」鍔熻兘銆傦紙ThinkPad T緋誨垪鍜孯緋誨垪鍩烘湰涓婇兘甯︽湁鍐呯疆鍏夐┍錛屽緢灝戜細浣跨敤鍒癠SB杞椹
鍜屽厜椹憋紝鍙浠ラ夋嫨Disabled錛沊 緋誨垪鍦ㄤ竴鑸鎯呭喌涓嬩篃鏄涓嶉渶瑕佷嬌鐢ㄥ埌 USB 杞椹卞拰鍏夐┍鐨勶紝涔熷彲浠ラ夋嫨
Disabled錛屼絾鍦ㄩ渶瑕乁SB鍏夐┍鍚鍔ㄧ殑鏃跺欙紝瑕侀夋嫨Enabled銆傦級
錛堝叚錛塊eyboard/Mouse錛堥敭鐩/ 榧犳爣錛
1 銆乀rackPoint錛堝皬綰㈢偣錛
浣跨敤TrackPoint 榧犳爣錛岃烽夋嫨 Enabled錛涢夋嫨 Automatic錛屽綋浠嬪叆 PS/2 錛圱hinkPad鏂版満鍨嬪凡涓嶅叿澶囷級鎺
鍙g殑榧犳爣鏃訛紝TrackPoint 榧犳爣灝嗚嚜鍔ㄥ仠鐢錛屽惁鍒欎竴鐩村勪簬鍚鐢ㄧ姸鎬併傦紙寤鴻閫夋嫨Automatic錛屽湪涓嶅悓鐜澧冧腑
鍙浠ラ潪甯告柟渚跨殑榪涜屽垏鎹銆傦級
2 銆乀ouchPad 錛堣Е鎺ф澘錛
浣跨敤TouchPad 錛岃烽夋嫨Enabled錛涢夋嫨 Automatic錛屽綋浠嬪叆PS/2 錛圱hinkPad鏂版満鍨嬪凡涓嶅叿澶囷級鎺ュ彛鐨
榧犳爣鏃訛紝TouchPad 灝嗚嚜鍔ㄥ仠鐢錛屽惁鍒欎竴鐩村勪簬鍚鐢ㄧ姸鎬併傦紙寤鴻閫夋嫨 Automatic錛屽湪涓嶅悓鐜澧冧腑鍙浠ラ潪甯
鏂逛究鐨勮繘琛屽垏鎹銆傦級
3 銆丗n key Lock錛團n閿閿佸畾錛
Enabled錛氭寜涓 Fn閿灝嗕繚鎸佹寜涓嬬殑鐘舵侊紝鐒跺悗鍐嶆寜涓嬫湡鏈涚殑鍔熻兘閿錛岀瓑浠蜂簬鍚屾椂鎸変笅Fn閿鍜岀浉搴旂殑鍔
鑳介敭銆傚綋浣犳寜涓 Fn閿涓ゆ$殑鏃跺欙紝灝嗗勪簬閿佸畾鐘舵侊紝鐩村埌鍐嶆℃寜涓嬩竴嬈Fn錛汥isabled錛氱佺敤姝ら」鍔熻兘銆傦紙鏍
鎹瀹為檯闇瑕佽繘琛岄夋嫨錛屼笉鍋氭帹鑽愩傦級
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 3 欏 鍏 9 欏
4 銆乀hinkPad Numlock 錛圱hinkPad 鏁板瓧閿鐩橈級
閫夋嫨Independent 錛屽綋浣跨敤澶栨帴閿鐩樻椂錛孴hinkPad 涓婄殑鏁板瓧閿鍙鑷鍔ㄥ叧闂錛涘綋 ThinkPad 鏁板瓧閿鍚鐢ㄦ椂錛
澶栨帴閿鐩樼殑鏁板瓧閿鍚屾牱鏈夋晥錛涢夋嫨 Synchronized錛屽垯琛ㄧず鍚屾ャ傦紙鏈欏逛繚鎸侀粯璁Independent鍗沖彲錛屼笉闇鐗
鍒璁劇疆銆傦級
錛堜竷錛塂isplay錛堟樉紺猴級
1 銆丏efault Primary Video Device錛堥粯璁や富瑕佹樉紺鴻懼囷級
Internal錛歍hinkPad 鍐呯疆鏄懼崱錛堟棤璁烘槸闆嗘垚鏄懼崱榪樻槸鐙絝嬫樉鍗★級錛汸CI-Express錛歍hinkPad 鎵╁睍鍧濸CI-E
鐙絝嬫樉鍗°傦紙涓鑸閫夋嫨Internal錛涘傛灉浣跨敤浜嗘墿灞曞潪騫舵坊鍔犱簡PCI-E鏄懼崱錛屽彲閫夋嫨PCI-Express銆傦級
2 銆丅oot Display Deice 錛堝惎鍔ㄦ樉紺鴻懼囷級
鏈欏規嫢鏈塗hinkPad LCD銆丄nalog 錛圴GA錛夈乂GA+LCD 銆丏igital 錛圖VI 錛夈丏VI+LCD銆乂GA+DVI 絳変簲
涓閫夐」銆傦紙鏍規嵁鎯呭喌榪涜岄夋嫨錛屽緩璁閫夋嫨ThinkPad LCD銆傦級
3 銆丅rightness
閫夋嫨LCD鐨勬槑浜搴︼紝High 錛氶珮浜搴︼紝Normal錛氭櫘閫氫寒搴︺傦紙寤鴻淇濇寔榛樿ょ殑Normal錛岄夋嫨High鉶藉彲
浠ユ彁楂樻樉紺虹殑浜搴︼紝涔熷皢緙╃煭浣跨敤鐢墊睜鎯呭喌涓嬬殑鐢墊睜浣跨敤鏃墮棿鍜孡CD鏄劇ず灞忕殑瀵垮懡錛夈
錛堝叓錛塒ower錛堢數婧愶級錛堟湰閫夐」涓嬫墍鏈夊瓙閫夐」寤鴻淇濇寔榛樿よ劇疆錛屽洜涓洪儴鍒嗛夋嫨鍦ㄧ郴緇熼噷闈涔熷彲璋冩暣鐢
婧愭柟妗堬紝濡傛湁鐗瑰埆璇存槑鍙鏍規嵁瀹為檯榪涜岃皟鏁淬傦級
1 銆乀ime Wake with Battery Operation
Enabled錛氬傛灉榪炴帴浜嗙數奼犲苟鍚鐢ㄤ簡鏈閫夐」錛孴hinkPad 鍙鑳戒細鑷鍔ㄥ惎鍔錛岃繖鏍鋒湁鍙鑳藉艱嚧鏈哄櫒鑷鍔ㄥ紑
鏈猴紝浠庤屾湁鍙鑳藉艱嚧紜鐩樻晠闅滆屽け鍘諱繚淇錛涘彟澶栵紝濡傛灉鏈哄櫒淇濆瓨浜嗕竴涓棰勮捐″垝錛屽湪絳夊緟榪囩▼涓鐢墊睜灝嗕細
娑堣楁畣灝斤紱Disabled錛氱佺敤姝ら」鍔熻兘錛屾満鍣ㄤ細蹇借嗚繖涓棰勮劇殑鍞ら啋璁″垝錛岀洿鍒拌繛鎺ヤ簡 AC 鐢墊簮錛屼互淇濇姢紜
浠躲傦紙寤鴻閫夋嫨Disabled銆傦級
2 銆両ntel 錛圧錛 SpeedStep Technology
Intel 鐨凜PU 鑷鍔ㄨ皟棰戞妧鏈錛岀被浼間簬 AMD澶勭悊鍣ㄧ殑3DNOW 錛侊紝姝ら」鍔熻兘涓鑸闆嗘垚鍦ㄥ湪 Intel 澶勭悊鍣ㄤ腑
楂樼浜у搧涓錛屼綆絝鐨勮禌鎵珻PU 涓嶆敮鎸併傦紙寤鴻瓻nable錛屽彲浠ユ湁鏁堟牴鎹瀹為檯宸ヤ綔鐨勮礋鑽瘋嚜鍔ㄨ皟鑺侰PU棰戠巼錛
鑺傝兘銆傦級
3 銆丮ode for AC錛堝栨帴鐢墊簮鏃剁數婧愭ā寮忥級錛堝緩璁淇濇寔榛樿わ紝涓嶅仛鎺ㄨ崘錛屽湪Windows涓嬮氳繃Power Manager
錛堢數婧愮$悊鍣錛変篃鍙璋冭妭銆傦級
錛1 錛塎aximum Performance錛氭渶澶фц兘錛孋PU 榪愯屽湪鏈楂橀戠巼
錛2 錛塀attery Optimized錛氱數奼犱紭鍖栵紝CPU 榪愯屽湪杈冧綆棰戠巼
錛3 錛塎aximum Battery錛氭渶澶х數奼犲垮懡
錛4 錛堿utomatic錛氳嚜鍔錛屾満鍣ㄥ皢鏍規嵁璐熻嵎鑷鍔ㄨ皟鑺傜數婧愮$悊鐘舵侊紙榛樿ょ姸鎬侊級
4 銆丮ode for Battery錛堜嬌鐢ㄧ數奼犳椂鐢墊簮妯″紡錛夛紙寤鴻淇濇寔榛樿わ紝涓嶅仛鎺ㄨ崘錛屽湪Windows涓嬮氳繃Power Manager
錛堢數婧愮$悊鍣錛変篃鍙璋冭妭銆傦級
錛1 錛塎aximum Performance錛氭渶楂樻ц兘錛孋PU 榪愯屽湪鏈楂橀戠巼
錛2 錛塀attery Optimized錛氱數奼犱紭鍖栵紝CPU 榪愯屽湪杈冧綆棰戠巼錛堥粯璁ょ姸鎬\錛
錛3 錛塎aximum Battery錛氭渶澶х數奼犲垮懡
錛4 錛堿utomatic錛氳嚜鍔錛屾満鍣ㄥ皢鏍規嵁璐熻嵎鑷鍔ㄨ皟鑺傜數婧愮$悊鐘舵
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 4 欏 鍏 9 欏
5 銆丄daptive Thermal Management 錛堥傚簲鎬х儹鑳界$悊錛
錛1 錛塖cheme For AC錛欰C鐢墊簮璁″垝
鈶燤aximize Performanced 錛氭渶楂樻ц兘錛堥粯璁ょ姸鎬\錛
鈶Balanced 錛氭ц兘騫寵
錛2 錛塖cheme For Battery 錛氱數奼犺″垝
鈶燤aximize Performanced 錛氭渶楂樻ц兘
鈶Balanced 錛氭ц兘騫寵錛堥粯璁ょ姸鎬\錛
娉ㄦ剰錛氭棤璁哄摢縐嶇數婧愯″垝錛岄兘浼氬獎鍝嶅埌椋庢墖鐨勫0闊熾佹俯搴﹀拰鎬ц兘銆
6 銆丆D-ROM Speed 錛堝厜椹遍熷害錛
鍙閫夋嫨Slient錛屼綆閫燂紙瀹夐潤錛夛紱Normal鏅閫氶熷害錛汬igh 楂橀熴傦紙寤鴻閫夋嫨Slient鎴朜ormal錛屽彲鍚屾椂鍏
欏懼厜椹卞垮懡鍜屽埢褰曞厜鐩樼殑璐ㄩ噺錛涢夋嫨High鏄撻犳垚鍏夐┍榪囨棭鐨勮佸寲錛屽噺灝戝垮懡銆傦級
7 銆丆PU Power Management錛圕PU 鐢墊簮綆$悊錛
Automatic錛氱郴緇熻嚜鍔ㄨ皟鑺傦紱Disabled錛氱佺敤銆傦紙寤鴻閫夋嫨Automatic錛岀敱緋葷粺鑷鍔ㄨ皟鑺傦紝鏈夊埄浜庤妭鑳姐傦級
8 銆丳CI Bus Power Management 錛圥CI 鎬葷嚎鐢墊簮綆$悊錛
Automatic錛氱郴緇熻嚜鍔ㄨ皟鑺侾CI 鎬葷嚎鐢墊簮錛汥isabled錛氱佺敤銆傦紙寤鴻閫夋嫨Automatic錛岀敱緋葷粺鑷鍔ㄨ皟鑺傦紝
鏈夊埄浜庤妭鑳姐傦級
錛堜節錛堿larm 錛堣﹀憡錛
1 銆丳ower Control Beep錛堢數婧愭帶鍒舵彁紺洪煶錛
閫夋嫨Enable 錛屽綋絎旇版湰榪涘叆鎸傝搗/ 浼戠湢/ 榪炴帴浜ゆ祦鐢電瓑鐘舵佹椂錛岄兘浼氬彂鍑衡淏 鈥濅竴澹扮殑鎻愮ず闊籌紱褰撳栨帴鐢
婧愪腑鏂錛屼篃浼氬彂鍑衡淏 鈥濅竴澹扮殑鎻愮ず闊熾傦紙寤鴻閫夋嫨Enabled錛屽彲浠ラ傛椂鎻愰啋褰撳墠鐢墊簮浣跨敤鎯呭喌銆傦級
2 銆丩ow Battery Alarm 錛堢數奼犱綆鐢甸噺璀﹀憡錛
鐢墊睜榪涘叆浣庣數閲忕姸鎬佹椂錛屽皢浼氬彂鍑鴻﹀憡澹般傦紙寤鴻閫夋嫨Enabled錛屽彲浠ラ傛椂鎻愰啋鐢墊睜浣跨敤鎯呭喌錛屼互渚垮強
鏃跺厖鐢點傦級
3 銆丳assword Beep錛堝瘑鐮佹彁紺洪煶錛
閫夋嫨Enabled錛屽綋寮鏈鴻緭鍏ュ瘑鐮佹椂錛屼細鍙戝嚭鈥淏 鈥濈殑鎻愮ず闊熾傦紙寤鴻閫夋嫨Disabled銆傦級
錛堝嶮錛塎emory錛堝唴瀛橈級
Extended Memory Test錛屾墿灞曞唴瀛樻祴璇曪紝Enabled錛屽惎鐢ㄥ唴瀛樻祴璇曪紝鍚屾椂緋葷粺鍚鍔ㄦ椂闂翠篃灝嗗歡闀匡紱Disabled
鍒欑佺敤銆傦紙寤鴻璁劇疆涓篋isabled錛屼竴鑸鏋佸皯浣跨敤鍒拌ュ姛鑳姐傦級
錛堝嶮涓錛塖erial ATA 錛圫ATA錛
鏈欏規槸閫夋嫨SATA 鎺у埗妯″紡錛孉HCI鏄瘲ATA 妯″紡錛堝傛灉紜鐩樻槸SATA鎺ュ彛錛屽緩璁閫夋嫨鏈欏規彁鍗囩‖鐩樻
鑳姐傦級錛汣ompatibility 鏄鍏煎規ā寮忥紙濡傛灉鎯崇嫭鑷瀹夎呮搷浣滅郴緇燂紝寤鴻鍏堣劇疆涓烘湰閫夐」錛岄伩鍏嶅畨瑁呰繃紼嬩腑钃濆睆
鐜拌薄鐨勫彂鐢熴傦級銆
錛堝嶮浜岋級CPU
1 銆丆ore Muti-Processing 錛堥粯璁ゆ槸 Enabled錛
Enabled錛氬皢鍚鐢ㄥ氭牳蹇冿紱Disabled錛氬崟鏍稿績榪愯屻傦紙澶氭牳蹇冪殑CPU錛屽緩璁閫夋嫨Enabled鍚鐢ㄥ氭牳蹇冿紝浣
楠屽氭牳蹇冨勭悊浠誨姟鏃剁殑鏂逛究錛涘綋鏌愪簺紼嬪簭浠呮敮鎸佸崟鏍稿績榪愯屾椂鍊欙紝璇烽夋嫨Disabled銆傦級
2 銆両ntel Virtualization Technology 錛圛ntel 鉶氭嫙鍖栨妧鏈錛夛紙榛樿ゆ槸Disabled錛
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 5 欏 鍏 9 欏
Enabled錛氬惎鐢 VT鎶鏈錛汥isabled錛氱佺敤 VT鎶鏈銆傦紙濡傛灉ThinkPad涓婂畨瑁呮湁鉶氭嫙鏈猴紝姣斿俈irtual 2007錛
寤鴻閫夋嫨Enabled銆傦級
錛堝嶮涓夛級Intel 錛圧錛 AMT 錛圛ntel Active Mana gement Technology錛
鑻辯壒灝斾富鍔ㄧ$悊鎶鏈錛岄渶瑕佸唴緗緗戝崱鍚鐢ㄣ傦紙涓浜虹敤鎴鳳紝鎺ㄨ崘閫夋嫨Disabled錛
涓夈丏ata/Time錛堟棩鏈/鏃墮棿錛
錛堜竴錛塖ystem Date錛堢郴緇熸棩鏈燂級
錛堜簩錛塖ystem Time錛堢郴緇熸椂闂達級
錛堜互涓婁袱欏逛竴鑸涓嶉渶瑕佺壒鍒璁劇疆錛屾牴鎹瀹為檯鎯呭喌榪涜岃皟鏁村嵆鍙銆傦級
鍥涖丼ecurity錛堝畨鍏錛
錛堜竴錛塒assword錛堝瘑鐮侊級錛堢壒鍒娉ㄦ剰錛氭湰閫夐」涓嬫墍鏈夊瓙閫夐」鐨勫瘑鐮侀渶瑕佺墷璁幫紝鍚﹀垯鍑犱箮鏃犳硶鐮磋В銆傦級
1 銆乁sing Passphrase
Enabled錛歋upervisor錛孭ower-On錛孒ard Disk鐨勫瘑鐮侀暱搴﹀彲浠ユ敮鎸佸埌64浣嶄釜鎬ч暱搴︼紝鍙鍖呭惈絀烘牸錛汥isabled錛
Supervisor錛孭ower-On錛孒ard Disk鐨勫瘑鐮侀暱搴︽渶闀誇負 7 浣嶉暱搴︺傦紙涓嶅仛寤鴻錛屾牴鎹闇瑕侀夋嫨銆傦級
2 銆丼upervisor Password錛堣秴綰у瘑鐮侊級
鑻ヨ劇疆姝ら」瀵嗙爜錛屽彲闃繪㈡湭鎺堟潈鐢ㄦ埛璁塊棶BIOS淇鏀笲IOS璁劇疆銆傦紙鎺ㄨ崘璁劇疆錛屼絾蹇呴』鐗㈣板瘑鐮侊紝ThinkPad
鐨勮秴綰у瘑鐮佹槸璁板綍鍦ㄥ畨鍏ㄨ姱鐗囬噷鐨勩傦級
3 銆丩ock BIOS Setting 錛堥攣瀹 BIOS璁劇疆錛
Enabled錛氶槻姝㈡湭鎺堟潈鐢ㄦ埛淇鏀 BIOS璁劇疆錛汥isabled錛氱佺敤銆傛湰欏瑰姛鑳戒粎鍦 Supervisor Password 璁劇疆
鏃舵墠鏈夋晥銆
4 銆丼et Minmum Length錛堣懼畾瀵嗙爜鏈灝戦暱搴︼紝鏍規嵁闇瑕佽繘琛岃劇疆銆傦級
涓鏃﹁懼畾瀵嗙爜鏈灝戦暱搴︼紝Power-On Password鍜孒ard Disk Password蹇呴』絳変簬鎴栭暱浜庤繖涓浣嶆暟錛涘惁鍒欙紝
瀵嗙爜闀垮害浣嶄簬1 鑷64 浣嶄箣闂淬
5 銆丅IOS Password at Unattended Boot
Enabled錛氬綋緋葷粺浠庝紤鐪犱腑鍞ら啋鎴栬呮槸鏈棰勬湡鐨勫惎鍔錛堟瘮濡俉ak e On Lan錛夛紝鎻愮ず杈撳叆BIOS 瀵嗙爜錛
Disabled錛氱佺敤姝ら」鍔熻兘錛屼笉鎻愮ず BIOS瀵嗙爜錛岀郴緇熺戶緇鍚鍔ㄣ傦紙闃叉㈡湭鎺堟潈鐢ㄦ埛璁塊棶ThinkPad錛屽緩璁閫夋嫨
Enabled銆傦級
6 銆丳ower-On Password錛堝紑鏈哄瘑鐮侊級
鑻ヨ劇疆姝ら」瀵嗙爜錛屾瘡嬈″紑鏈虹殑鏃跺欙紝闇瑕侀敭鍏ユg『鐨勫瘑鐮佹墠鑳藉紩瀵肩郴緇熴傦紙寮鏈哄瘑鐮佸彲閫氳繃闄ゅ幓涓繪澘
鐢墊睜鐮磋В銆傦級
7 銆丠ard Disk Password錛堢‖鐩樺瘑鐮侊級
璁劇疆紜鐩樺瘑鐮佸彲浠ラ樆姝㈡湭鎺堟潈鐨勭敤鎴瘋塊棶紜鐩樹笂鐨勬墍鏈夋暟鎹錛屽彧鏈夎緭鍏ユg『鐨勫瘑鐮佹墠鑳借塊棶銆傞氬父鏄
鍦ㄥ紑鏈烘椂瑕佹眰杈撳叆銆傛湰鎯蟲嫢鏈塙ser 鍜孶ser+Master涓ょ嶆柟寮忎緵閫夋嫨銆傦紙濡傚繕璁版ゅ瘑鐮佸垯鏃犳硶鐮磋В錛岃嫢紜鐩
涓婃棤鍗佸垎閲嶈佷箣鏂囦歡錛岃鋒厧鐢ㄣ傦級
8 銆丳assword Reset Service錛堝瘑鐮侀噸緗鏈嶅姟錛
濡傛灉鍚鐢ㄤ簡姝ゆ湇鍔★紝鍦ㄢ淪tar t鈫扐ll鈫扵hinkVantage鈫扖reate Recovery Media鈥濅腑鎸夌収鎻愮ず榪涜岀瓑綰с
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 6 欏 鍏 9 欏
浠ュ悗閬楀繕浜嗗瘑鐮侊紙Power-On Password鍜孒ard Disk Password錛夌殑鎯呭喌涓嬶紝鍙浠ュ湪寮鏈烘椂鎸 F12 閿榪涜屽瘑鐮
閲嶇疆銆
錛堜簩錛塅ingerprint 錛堟寚綰癸級
1 銆丳redesktop Autherication
Enabled錛氬湪 Predesktop 鍖哄煙闇瑕佹寚綰歸獙璇侊紱Disabled錛氬湪 Predesktop 鍖哄煙涓嶉渶瑕佽繘琛屾寚綰歸獙璇併傦紙寤鴻
閫夋嫨Enabled錛屾彁楂樺畨鍏ㄦс傦級
2 銆丷eader Priority錛堟寚綰硅瘑鍒鍣ㄤ紭鍏堟潈錛
Internal錛屽唴緗鎸囩汗璇嗗埆鍣錛汦xternal錛屽栫疆鎸囩汗璇嗗埆鍣ㄣ傦紙瀵逛簬闆嗘垚鎸囩汗璇嗗埆鍣ㄧ殑ThinkPad錛屽緩璁閫夋嫨
Internal錛涘傛灉浣跨敤浜嗗栫疆鐨勬寚綰硅瘑鍒鍣錛岃烽夋嫨External銆傦級
3 銆丼ecurity Mode 錛堝畨鍏ㄦā寮忥級
濡傛灉涓嶅瓨鍦ㄦ巿鏉冭よ瘉鐨勬寚綰規垨鎸囩汗璁よ瘉澶辮觸錛屽彲浠ラ氳繃杈撳叆瀵嗙爜鏉ュ惎鍔ㄨ$畻鏈恆侼ormal錛氳緭鍏ュ紑鏈哄瘑
鐮佹垨鑰呰秴綰х敤鎴峰瘑鐮佸惎鍔═hinkPad 錛汬igh錛氬繀欏昏緭鍏ヨ秴綰х敤鎴峰瘑鐮佸惎鍔 ThinkPad 銆傦紙鎺ㄨ崘閫夋嫨Normal錛
4 銆丒rase Internal Fingerprint Data
娓呴櫎鍐呯疆鎸囩汗璇嗗埆鍣ㄦ寚綰規暟鎹搴撱傦紙鎱庣敤錛侀櫎闈炴槸鎸囩汗璇嗗埆鍣ㄥ歸噺宸叉弧鐨勬儏鍐典笅錛屾竻闄や箣鍚庯紝闇瑕侀噸
鏂扮櫥璁版寚綰規暟鎹銆傦級
錛堜笁錛塖ecurity Chip 錛堝畨鍏ㄨ姱鐗囷級
1 銆丼ecurity Chip
Activate錛氬惎鐢ㄥ畨鍏ㄨ姱鐗囷紱Inactivate 錛氬畨鍏ㄨ姱鐗囧彲瑙侊紝浣嗕笉鐢熸晥錛汥isabled錛氬畨鍏ㄨ姱鐗囬殣鈃忎笖涓嶇敓鏁堛
錛堟牴鎹鑷宸遍渶瑕佽繘琛屾洿鏀癸紝寮鍚瀹夊叏鑺鐗囪兘澧炲己璁$畻鏈虹殑瀹夊叏鎬э紝浣嗗悓鏃朵篃鍙鑳藉甫鏉ヤ竴浜涗笉蹇呰佺殑楹葷儲銆傦級
2 銆丼ecurity Reporting Options錛堝畨鍏ㄨ姱鐗囨姤鍛婇夋嫨錛夛紙褰撲笖浠呭綋瀹夊叏鑺鐗嘇ctivate鐨勬椂鍊欙紝鏈閫夐」鍙
鎿嶄綔錛屽緩璁淇濇寔榛樿Disabled銆傦級
錛1 錛塀IOS Rom String Reporting錛欱IOS鏂囨湰瀛楃︿覆鎶ュ憡
錛2 錛塃SCP Reporting錛氭墿灞曠郴緇熼厤緗鏁版嵁鎶ュ憡
錛3 錛塁MOS Reporting錛欳MOS 鏁版嵁鎶ュ憡
錛4 錛塏VRAM Reporting 錛氬偍鍦ˋsset 鏍囪瘑涓鐨勫畨鍏ㄦф暟鎹鎶ュ憡
錛5 錛塖MBIOS Reporting 錛歋MBIOS 鎶ュ憡
3 銆丆lear Security Chip 錛堟竻絀哄姞瀵嗗瘑閽ワ級
娉ㄦ剰錛氭ら」姝e父鎯呭喌涓婤IOS閲岄潰涓嶆樉紺猴紝濡傝佹樉紺猴紝鍙鎸夊備笅鎿嶄綔錛氬紑鏈鴻繘鍏LOGO澶勶紝鎸夌數婧愰敭鍏
鏈猴紝鍐嶆″紑鏈烘寜F1榪涘叆BIOS鍙瑙侊紙鎴栧湪寮鍚疶hinkPad鏃舵寜Fn+F1錛孲hift+F1緇勫悎閿錛夈傚綋娓呯┖浜嗗瘑閽ュ悗錛
鍘熷厛鍔犲瘑鐨勫唴瀹規棤娉曟墦寮銆
錛堝洓錛塀IOS Update Option
Flash BIOS Updating By End-users錛堢粓絝鐢ㄦ埛鍙鍗囩駭 BIOS錛夛紝Enabled錛氬彲浠ュ啓鍏ユ柊鐗堟湰 BIOS錛汥isabled錛
紱佹㈠啓鍏ユ柊鐗堟湰BIOS銆傦紙濡傛灉闇瑕佸埛鏂 BIOS錛屾湰閫夐」涓瀹氳侀夋嫨 Enabled錛涜嫢涓嶆兂鍒鋒柊 BIOS錛屾湰閫夐」鍙
閫夋嫨Disabled銆傦級
錛堜簲錛塎emory Protection
Execution Prevention 錛氭よ懼畾鑳介伩鍏嶇棶姣掑拰錩曡櫕寮曡搗鍐呭瓨緙撳啿婧㈠肩殑鏀誨嚮錛岄渶瑕佹搷浣滅郴緇熸敮鎸侊紝榛樿
鍗沖彲銆
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 7 欏 鍏 9 欏
錛堝叚錛塈/O Port Access 錛堟湰閫夐」涓昏佹槸瀵筎hinkPad涓婄‖浠剁殑鎺у埗錛岄槻姝㈡湭鎺堟潈鐢ㄦ埛浣跨敤銆傦級
1 銆丒thernet LAN
Enabled錛氬惎鐢ㄥ唴緗鏈夌嚎鍗冨厗緗戝崱錛汥isabled錛氱佺敤鏈夌嚎鍗冨厗緗戝崱錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙涓鑸
閫夋嫨Enabled錛涘傛灉緇忓父浣跨敤鏃犵嚎緗戝崱涓婄綉錛屽彲閫夋嫨Disabled銆傦級
2 銆乄irless LAN
Enabled錛氬惎鐢ㄥ唴緗鏃犵嚎緗戝崱錛汥isabled錛氱佺敤緗戠嚎緗戝崱錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙涓鑸閫夋嫨
Enabled錛涘傛灉涓嶄嬌鐢ㄦ棤綰跨綉鍗′笂緗戱紝鍙閫夋嫨Disabled銆傦級
3 銆乄ireless WAN
Enabled錛氬惎鐢ㄥ唴緗鏃犵嚎騫垮煙緗戠綉鍗★紱Disabled錛氱佺敤鏃犵嚎騫垮煙緗戠綉鍗★紝騫朵繚鎸佸湪緋葷粺鐜澧冧笅涓嶅彲瑙併
錛堜竴鑸閫夋嫨Disabled錛屽湪澶ч檰寰堝皯鐢ㄥ埌銆傦級
4 銆丅luetooth
Enabled錛氬惎鐢ㄨ摑鐗欒懼囷紱Disabled錛氱佺敤钃濈墮璁懼囷紝騫朵繚鎸佸湪緋葷粺鐜澧冧笅涓嶅彲瑙併傦紙鍐呯疆钃濈墮妯″潡鐨勬満
鍨嬶紝鎺ㄨ崘閫夋嫨Enabled錛屽惁鍒欙紝璇烽夋嫨Disabled銆傦級
5 銆乄ireless USB
Enabled錛氬惎鐢ㄦ棤綰 USB 璁懼囷紱Disabled錛氱佺敤鏃犵嚎 USB 璁懼囷紝騫朵繚鎸佸湪緋葷粺鐜澧冧笅涓嶅彲瑙併傦紙娌℃湁鍐
緗鏃犵嚎USB璁懼囩殑錛屾帹鑽愰夋嫨Disabled錛涘惁鍒欙紝璇烽夋嫨Enabled銆傦級
6 銆丮odem
Enabled錛氬惎鐢ㄥ唴緗 Modem錛汥isabled錛氱佺敤Modem錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙Modem鐜板湪鍩烘湰
涓婃窐奼頒簡錛屾帹鑽愰夋嫨Disabled銆傦級
7 銆乁SB Port
Enabled錛氬惎鐢 USB 鎺ュ彛鏀鎸侊紱Disabled錛氱佺敤 USB 鎺ュ彛鏀鎸侊紝騫朵繚鎸佸湪緋葷粺鐜澧冧笅涓嶅彲瑙併傦紙鎺ㄨ崘閫
鎷〦nabled銆傦級
8 銆両EEE 1394
Enabled錛氬惎鐢 1394鎺ュ彛錛汥isabled錛氱佺敤 1394鎺ュ彛錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙鍐呯疆1394鎺ュ彛
鐨勭殑鏈哄瀷錛屾帹鑽愰夋嫨Enabled錛屽惁鍒欙紝璇烽夋嫨Disabled銆傦級
9 銆丼erial Port
Enabled錛氬惎鐢ㄤ覆鍙o紱Disabled錛氱佺敤涓插彛錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙ThinkPad 鏂版満鍨嬪熀鏈涓婂彇
娑堜簡鍐呯疆鐨勪覆鍙o紝鑰屼笖涓插彛涓鑸浜虹幇鍦ㄥ緢灝戠敤鍒幫紝鎺ㄨ崘閫夋嫨Disabled銆傦級
10銆丳arallel Port
Enabled錛氬惎鐢ㄥ苟鍙o紙鎵撳嵃鏈烘帴鍙o級錛汥isabled錛氱佺敤騫跺彛錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙ThinkPad鏂
鏈哄瀷鍩烘湰涓婂彇娑堜簡鍐呯疆鐨勫苟鍙o紝鑰屼笖騫跺彛涓鑸浜虹幇鍦ㄥ緢灝戠敤鍒幫紝鎺ㄨ崘閫夋嫨Disabled銆傦級
11 銆丆ardBus Slot
Enabled錛氬惎鐢 CardBus 鎻掓Ы錛汥isabled錛氱佺敤 CardBus 鎻掓Ы錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙緇忓父浣跨敤
鍒癈ardBus璁懼囩殑錛屾帹鑽愰夋嫨Enabled銆傦級
12銆丒xpressCard Slot
Enabled錛氬惎鐢 ExpressCard鎻掓Ы錛汥isabled錛氱佺敤 ExpressCard鎻掓Ы錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併傦紙緇
甯鎬嬌鐢ㄥ埌CardBus璁懼囩殑錛屾帹鑽愰夋嫨Enabled銆傦級
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 8 欏 鍏 9 欏
13銆丳CI Express Slot
Enabled錛氬惎鐢ㄥ唴緗 PCI Express 鎻掓Ы錛汥isabled錛氱佺敤 PCI Express 鎻掓Ы錛屽苟淇濇寔鍦ㄧ郴緇熺幆澧冧笅涓嶅彲瑙併
錛堢粡甯鎬嬌鐢ㄥ埌PCI-E璁懼囩殑璇濓紝璇烽夋嫨Enabled銆傦級
14銆乁ltrabay錛圚DD/Optocal錛
Enabled錛氬惎鐢 Ultrabay錛堢‖鐩/ 鍏夐┍錛夛紱Disabled錛氱佺敤 Ultrabay錛堢‖鐩/ 鍏夐┍錛夛紝騫朵繚鎸佸湪緋葷粺鐜澧冧笅涓
鍙瑙併傦紙鎺ㄨ崘閫夋嫨Enabled銆傦級
15銆丮icrophone
Enabled錛氬惎鐢ㄩ害鍏嬮庯紱Disabled錛氱佺敤楹﹀厠椋庯紝騫朵繚鎸佸湪緋葷粺鐜澧冧笅涓嶅彲瑙併傦紙鎺ㄨ崘閫夋嫨Enabled錛屽湪
璇闊寵亰澶╂椂闈炲父鏈夌敤銆傦級
浜斻丼tartup錛堝惎鍔ㄩ夐」錛
錛堜竴錛塀oot錛堝惎鍔錛
鎸塅5/F6 鍙浠ユ洿鏀規墍鍒楄懼囩殑鍚鍔ㄩ『搴忋傦紙寤鴻璁劇疆錛氱‖鐩樹負絎涓鍚鍔ㄩ夋嫨錛屽厜椹變負絎浜屽惎鍔ㄩ夋嫨錛
鍙浠ョ緝鐭緋葷粺寮鏈鴻嚜媯鏃墮棿銆傦級
錛堜簩錛塏etwork錛堢綉緇滃惎鍔ㄩ『搴忛夐」錛
鍚屼笂榪涜岃劇疆錛屾湰欏瑰逛釜浜虹敤鎴鋒剰涔変笉澶с
錛堜笁錛塀oot Mode 錛堝惎鍔ㄦā寮忥級
Quick錛氬揩閫熸ā寮忥紱Diagnostics 錛氭帓閿欐ā寮忋傦紙寤鴻閫夋嫨Quick妯″紡錛屽彲浠ョ緝鐭緋葷粺鍚鍔ㄦ椂闂達紝闄ら潪緋
緇熷嚭鐜伴棶棰樻垨鑰呮柊鏇存崲紜浠訛紝鍙閫夋嫨Diagnostics妯″紡銆傦級
錛堝洓錛塐ptions Keys Display
鏈閫夐」鎺у埗緋葷粺鍚鍔ㄦ椂鐨勪竴浜涙彁紺洪敭鐨勬樉紺猴紝姣斿侳1鍜孍sc閿錛孍nabled錛氬惎鐢ㄦ彁紺猴紱Disabled錛氱
鐢ㄦ彁紺恆傦紙寤鴻閫夋嫨Enabled錛
錛堜簲錛塀oot Device List F12 Option
閫夋嫨Enabled錛屽彲浠ュ湪寮鏈烘椂鎸変笅 F12 閿鏄劇ず鎵鏈夊惎鍔ㄨ懼囷紝騫跺彲涓存椂鏇存敼紜鐩/ 鍏夐┍/杞椹辯瓑璁懼囩殑鍚
鍔ㄩ『搴忥紱Disabled錛氱佺敤銆傦紙寤鴻閫夋嫨Enabled銆傦級
鍏銆丷estart錛堥噸鏂板惎鍔錛夛紙鏈閫夐」鏃犵壒鍒瑕佹眰娉ㄦ剰鐨勶紝璇鋒嵁瀹為檯鎯呭喌榪涜岄夋嫨鍗沖彲銆傦級
錛堜竴錛塃xit Saving Changes
閫鍑轟笖淇濆瓨鏇存敼鐨凚IOS璁劇疆
錛堜簩錛塃xit Discarding Changes
閫鍑轟絾涓嶄繚瀛樻洿鏀圭殑BIOS璁劇疆
錛堜笁錛塋oad Setup Defaults
鎮㈠嶉粯璁ょ殑BIOS璁劇疆
錛堝洓錛塂iscard Changes
鍙栨秷鎵鏇存敼鐨凚IOS璁劇疆
錛堜簲錛塖ave Changes
淇濆瓨鎵鏇存敼鐨凚IOS璁劇疆
銆奣hinkPad BIOS 璁劇疆鎵嬪唽銆嬶紙T61&T61P 鐗堬級 絎 9 欏 鍏 9 欏
娉錛氳劇疆榪囩▼涓錛屾寜F9閿鍒欏彲浠ユ仮澶嶅師鍘傞勮懼ソ鐨凚IOS璁劇疆錛堝湪鍒鋒柊BIOS鍚庨渶瑕佽繘琛屾柊鐗圔IOS鐨
鍒濆嬪寲鎿嶄綔錛夛紝鎸塅10閿鍒欎繚瀛樿劇疆騫墮噸鏂板惎鍔ㄣ
涓冦丠DD Diagnostics Program錛堢‖鐩樿瘖鏂紼嬪簭錛
BIOS 闆嗘垚鐨勭‖鐩樿瘖鏂紼嬪簭錛屽彲浠ユ嫻嬬‖鐩樿誨啓姝e父涓庡惁錛屼篃鍙浠ヨ瘖鏂鍏夐┍浣嶇‖鐩橈紝鑰楁椂澶х害鏄
1GB/1Min銆
⑵ 瓚呯駭钃濈墮妯″潡甯wifi鏈変粈涔堢敤
1錛屽紑鍚钃濈墮璁懼囧紑鍏(on/off)錛屽悓鏃朵繚鎸佺數瑙嗚摑鐗欏紑鍏充負寮鍚鐘舵併
2錛屾寜钃濈墮璁懼囩殑鈥渃onnect鈥濇寜閽錛屽紑鍚榪炴帴鐘舵侊紝姝ゆ椂鐢佃嗘満鎵嶅彲浠ユ悳緔㈠埌钃濈墮璁懼囷紝濡傛灉浠呬粎寮鍚鐢墊簮寮鍏寵屼笉鈥渃onnect鈥濆彂閫佽摑鐗欎俊鍙鳳紝鐢佃嗘満涔熸槸鏃犳硶鎼滅儲鍒扮殑銆
3錛屽悓鏃舵敞鎰忥紝鐢佃嗘満寮鍚钃濈墮鍚庯紝鏄鏈20s鐨勬悳緔㈡椂闂達紝瓚呰繃20s鍚庝細鑷鍔ㄥ仠姝㈡悳緔銆(鏆傛椂鏈鍋氭墜鍔ㄦ悳緔㈠姛鑳)闇瑕佹帹鍑鴻摑鐗欓〉闈㈤噸鏂拌繘鍏ユ縺媧繪悳緔㈡垨鑰呴噸鏂板叧闂鎵撳紑寮鍏蟲縺媧繪悳緔銆
4錛屽湪鎼滅儲鍒拌摑鐗欒懼囧苟閫夋嫨鍚庡彲浠ユ樉紺洪厤瀵規垚鍔熴